Journal of immunological methods
Recommendations for the design and optimization of immunoassays used in the detection of host antibodies against biotechnology products
Abstract
Most biopharmaceutical therapeutics elicit some level of antibody response against the product. This antibody response can, in some cases, lead to potentially serious side effects and/or loss of efficacy. Therefore, the immunogenicity of therapeutic proteins is a concern for clinicians, manufacturers and regulatory agencies. In order to assess immunogenicity of these molecules, appropriate detection, quantitation and characterization of antibody responses are necessary. Inadequately designed antibody assays have led to the hampering of product development or, during licensure, post-marketing commitments. This document provides scientific recommendations based on the experience of the authors for the development of anti-product antibody immunoassays intended for preclinical or clinical studies. While the main focus of this document is assay design considerations, we provide scientific focus and background to the various assay performance parameters necessary for developing a valid assay. Sections on assay performance parameters, including those that appear in regulatory guidances, are contained in this manuscript.
Source and rights
Published by Journal of immunological methods, 2004. The guideline itself is at the source linked here.
Prognia summarises this guideline for reference and education. It is not medical advice. Always check the official guideline and current local protocols before acting on it.
At a glance
- Published
- 2004
- Applies to
- 🌐 International
- Country of origin
- 🇺🇸 United States
- Scope
- International