Reviews in cardiovascular medicine
Application of Non-Invasive Cardiac Output Monitoring in Enhanced Recovery After Surgery for Patients With Acute Type A Aortic Dissection
By Zheng J, Xiao X, Ye Z and 6 others.
Abstract
Background
To assess the clinical value of non-invasive cardiac output monitoring (NICOM) within an enhanced recovery after surgery (ERAS) protocol for patients undergoing acute type A aortic dissection (ATAAD) repair.
Methods
This study included 242 patients who underwent total arch replacement for ATAAD between January 2024 and June 2025. Patients were stratified into two groups based on postoperative NICOM use (NICOM group, n = 141; control group, n = 101). This study compared hemodynamic parameters, 6-minute walk test (6MWT) results, postoperative recovery, and complications.