Bioengineering
Accuracy of Intraocular Lens Power Calculation Formulas for Two Single-Piece Acrylic IOL Models in Eyes with a Shallow Anterior Chamber
Par Yalan Wang, Wei Lou, Lu Liu et 4 autres.
Contenu en anglais
Résumé
Introduction
This study evaluated whether the refractive prediction accuracy of conventional and new-generation intraocular lens (IOL) power calculation formulas differs between two single-piece acrylic IOL models in eyes with a shallow anterior chamber depth (ACD).
Methods
In total, 100 eyes implanted with Softec HD IOLs (Lenstec) and 102 eyes implanted with SN60WF IOLs (Alcon) were included. All eyes had an ACD of ≤3.0 mm. The prediction error (PE) and mean absolute error (MAE) of 11 formulas, with and without optimized constants, were evaluated, including seven new-generation formulas (Barrett Universal II [BUII], Cooke K6 [K6], EVO 2.0, Hill-RBF 3.0, Hoffer QST, Kane, and Pearl-DGS) and four conventional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T).




